Dust Deflectors

ID Fan for pelletizing plant with dust deflectors painted yellow.

COVENT has applied this technology in high abrasion applications such as iron ore pelletizing plants. Service life has increased from 6 months to over 6 years. The dust deflectors are protected with chromium carbide wear plates and will need to be replaced as required. There are significant cost savings and increases in service life compared to complete rotor blade liner replacement.

Dust Deflectors keep dust suspended in the gas stream to reduce sliding wear on the blades

Key design features

The dust deflector blades are easily and quickly replaced through the inspections doors. The rotor does not need to be removed and the fan does not need to be dismantled.